Hogan's Creek District Cooling Plant

Jacksonville, Florida

  • Solutions: District Energy
  • Markets: Power Generation & Utilities
  • Services: , Fabrication & Installation, Service Agreements, Start-Up & Commissioning
Project Scope

Stellar Energy provided turnkey delivery of a central chilling plant that distributes and circulates approximately 10,000 tons of chilled water to facilities. Stellar Energy also designed, fabricated and installed in-ground and above-ground insulated chilled-water distribution piping as large as 30 inches.

 

Project Challenge

When the city of Jacksonville launched a public initiative to invest in infrastructure and public facilities, a new events arena and baseball park were constructed at the city’s sports center downtown. The Jacksonville Electric Authority (JEA) planned a district cooling plant near the complex to efficiently supply chilled water to the sports facilities through underground supply and return distribution pipes. The chilled water would then be used by each client facility to provide comfort cooling via air-handling units and cooling coils within the facilities. Additionally, JEA was required to provide mission critical standby chilled water service in the event of a power outage.

 

Project Solution

Stellar Energy provided comprehensive design-build services for the JEA Hogan’s Creek Chilled Water District Cooling Plant, including engineering, design, equipment procurement, construction, mechanical services, fabrication, installation and commissioning for the project. The project included three chillers for a total capacity of 12,000 TR. The field-erected tower has a capacity of 33,600 GPM. 

To address the requirement for mission-critical cooling in the event of a power outage, Stellar Energy designed and installed a one million-gallon thermal energy storage tank and a 600 KW emergency generator at the plant. This solution allows the plant to continue to supply chilled water to the arena even during a power outage at the plant. The tank is a stratified chilled water design and is maintained at the design water temperature prior to an event at the arena. When power is lost, the emergency generator will automatically activate and run the necessary pumping and controls to supply the arena’s air conditioning during an event.

With the success of the Hogan’s Creek District Cooling Plant, JEA retained Stellar Energy for two subsequent district cooling projects: JEA Downtown District Cooling Plant and the JEA Shands Hospital District Cooling Plant.